Technical Specs for The Cold Box™
Please click here to download our brochure.
Cooling system:
High efficiency forced-air DC compression cooling
R134A refrigerant
Heating System
Forced air resistance heating for lower band limit
Controls:
High efficiency electronic controls of compressor motor, fans, and heater.
High precision, 0.18°F (0.10°C) thermistor temperature sensors.
Battery system:
AGM deep discharge lead-acid batteries connected in series/parallel pairs fort 24 VDC.
Solid state high current charger with universal input (90-260 VAC, 1 Ph., 47-63 Hz)
Power Input:
115 VAC (50-60 Hz), 12A, or
230 VAC (50-60 Hz), 6A
Charger Output
24 VDC, 45 A
Other fixed and Adjustable Temperature Set Points on request.
Maximum operating temp:
130°F (54.4°C) ambient
Minium operating temp:
-10°F (-23 °C) ambient
Inside Container Dimensions
|
|
Height |
Width |
Length |
Actual |
|
40 cuft |
42" |
50" |
36" |
43.75 |
|
60 cuft |
42" |
50" |
50" |
60.76 |
80 cuft |
42" |
50" |
68" |
82.63 |
100 cuft |
42" |
50" |
84" |
102.08 |
|
120 cuft |
42" |
60" |
84" |
122.50 |
* WB, wide control band, NB, narrow control band.
** Before customer-selected battery set.
Outside Container Dimensions
|
|
Height |
Width |
Length |
|
40 cuft |
62" |
56" |
52" |
|
60 cuft |
62" |
56" |
66" |
|
80 cuft |
62" |
56" |
84" |
| 100 cuft | 62" | 56" | 100" |
|
120 cuft |
62" |
66" |